Biological nanoparticles such as extracellular vesicles (EVs), exosomes, viruses, or virus-like particles are in the growing interest of the biosciences and nanomedicine. With the NTA technology, particles are individually measurable in a physiological buffer and you observe what you measure in a video. A new step forward in convenience and speed for fluorescence studies of EV-antibody conjugates has been achieved with the ZetaView® TWIN. Lasers and fluorescence filters are pre-selectable via the software. This procedure saves time and sample.

Typical application

Determining the absolute concentration is one of the strengths of the NTA technique. In scatter mode, the concentration of all particles is measured. Changing subsequently to the fluorescence mode, marked biologic nanoparticles are tracked. By using two lasers within a SOP assisted sequence, it is possible to differentiate between two different fluorescence dyes in the same sample. Phenotyping of tetraspanins for instance, on vesicles and virus is facilitated, positive and isotype control as well. To prepare instrument settings, standard EVs may be used (HBM HansaBioMed https://www.hansabiomed.eu/).

  • very short measuring times
  • "Ready to use" calibration standard
  • 11 measuring positions, optionally combined with dosing steps
  • Outlier free result
  • sample recovery
  • Low Bleach Technology
  • Fully automatic focusing of the optics
  • Quartz cell channel and easy cleaning
  • SOP methodology
  • Applicable in the GMP range
  • IQ / OQ / PQ

  • 2 fluorescence channels per sample
  • Laser and fluorescence channels switched per mouse click
  • Choice of different fluorescence settings per SOP
  • Choice between the following laser combinations:
    • 405 nm and 488 nm
    • 405 nm and 520 nm
    • 405 nm and 640 nm
    • 488 nm and 640 nm
    • 520 nm and 640 nm

Example Application

Sales inquiry

Your contact data
Fields with * are mandatory!
Dr Genevieve Melling of Oxford Brookes University using the ZetaView® to study EVs

PMX Applications ZetaView Life Science Nanoparticle Tracking

Researchers at Oxford Brookes University use the ZetaView® to study extracellular vesicles.

The particular area of expertise focuses on investigating the roles of extracellular vesicles (EVs)...

Phenotyping of EVs by Multi-Wavelength Fluorescence Nanoparticle Tracking Analysis

PMX Applications ZetaView Life Science Nanoparticle Tracking

Phenotyping of EVs by Multi-Wavelength Fluorescence Nanoparticle Tracking Analysis

Nanoparticle Tracking Analysis of fluorescent labelled bionanoparticles, such as vesicles or...

Size measurement of SiO2 reference source on 5 different ZetaView 110 instruments. mode size according certificate 85.1 nm (orange line)

PMX Applications ZetaView Life Science Nanoparticle Tracking

Reliability of concentration measurements with the Particle Metrix ZetaView® Nanoparticle Tracking Analyzer

Concentration levels of extracellular vesicles have a high clinical potential as a reference for...

PMX Applications ZetaView Life Science

EV Isolation Yields confirmed via F-NTA

System Biosciences recommends ZetaView for fluorescent NTA analysis.

A CellGS scientist uses the Particle Metrix ZetaView for the study of exosomes

Applications ZetaView Life Science

Cell Guidance Systems use the ZetaView from Particle Metrix for exosome research and quality control.

Meerbusch, 12th July, 2016: Particle Metrix, developers of versatile particle characterization...

Michel Bremer from UK Essen using the Particle Metrix ZetaView system to characterise EVs.

Applications ZetaView Life Science

The Institute for Transfusion Medicine at the University Hospital of Duisburg-Essen in Germany uses the ZetaView from Particle Metrix to quantify extracellular vesicles.

Meerbusch, 7th June, 2016: Particle Metrix, developers of versatile particle characterization...

Jochen Dindorf with his Zetaview particle characterization system from Particle Metrix

Applications ZetaView Life Science

The Translational Research Center at the University Hospital of Erlangen in Germany uses the ZetaView from Particle Metrix to quantify extracellular vesicles such as exosomes.

Meerbusch, April 28th, 2016: Particle Metrix, developers of versatile particle characterization...

Dr Dylan Burger with his ZetaView particle characterization system from Particle Metrix

Applications ZetaView Life Science

The Ottawa Hospital Research Institute uses the ZetaView from Particle Metrix to study membrane microparticles as potential biomarkers for underlying diseases.

Meerbusch, April 12th, 2016: Particle Metrix, developers of versatile particle characterization...

Dr Yutao Liu from Augusta University with his Particle Metrix ZetaView system

Applications ZetaView Life Science

Augusta University’s Department of Cellular Biology & Anatomy is studying exosomes using ZetaView from Particle Metrix to aid in identification of potential biomarkers.

Meerbusch, March 31st, 2016: Particle Metrix, developers of versatile particle characterization...

image-817

Applications NANO-flex ZetaView Life Science Nanoparticle Tracking

Three in One: Concentration, Size & Zeta Potential measured on sub-visible protein suspensions

The preparation of high-value biological material, such as proteins, requires a multi-step procedure...

PMX Applications News ZetaView Life Science

An Innovative Method for Exosome Quantification and Size Measurement

JoVE has published a video article utilizing ParticleMetrix's products for Exosome Quantification...

ZetaView® Layout

Applications ZetaView Life Science Nanoparticle Tracking

Elektrophorese & Elektroosmose

Elektrophorese, Zetapotential, Brownsche Partikelgröße, Elektroosmose direkt im...

image-120

Applications Stabino Particle Charge ZetaView Colloid Analysis

Zeta potential distribution of 1 nm particles

Below 5 nm, due to lack of signal, with most analytical systems it is difficult to measure...

ZetaView NTA-Zellkassette mit Blick auf die Ein- und Auslassöffnungen sowie den Durchfluss-Zellkanal.

PMX Technologies ZetaView Life Science Nanoparticle Tracking

Limitation of sample volume: How to recover a sample after NTA measurement

Full recovery of samples measured by a nanoparticle tracking analyzer (NTA) often becomes challenging particularly if the samples are intended for...

PMX Technologies Nanoparticle Tracking

How to measure the zeta potential of individual Nanoparticles (NPs)?

To anticipate the answer: With the ZetaView®.

ZetaView - High efficiency quantification of fluorescent labeled EVs with F-NTA

Technologies ZetaView Nanoparticle Tracking

High efficiency quantification of fluorescent labeled EVs with F-NTA

Nanoparticle Tracking Analysis (NTA) is an efficient technique for quantification of size and concentration such as virus, liposomes and EVs....

Surface Charge and Pattern Analysis -  Differentiating Tools in Scanning NTA

Technologies ZetaView Nanoparticle Tracking

Surface Charge and Pattern Analysis - Differentiating Tools in Scanning NTA

Nanoparticle Tracking Analysis (NTA) combined with surface charge measurement enables the user to gain bio-chemical information about particle...

ZetaView - With all Cell Assemblies, size, concentration and sub-population measurements are possible, in scattering and fluorescent mode

Technologies ZetaView Nanoparticle Tracking

The Scanning Nano Particle Tracking Analysis (NTA) ZetaView™ now for potentially hazardous samples

Particle Metrix now introduces two additional types of NTA Cell Assemblies: The new types are designed for concentration, size and fluorescence...

ZetaView Measurement Principle

Technologies ZetaView Nanoparticle Tracking

Introduction to Nanoparticle Tracking Analysis (NTA)

Measurement Principle of ZetaView®

Particle Tracking on Exosomes

Technologies ZetaView Nanoparticle Tracking

ZetaView® Particle Tracking on Exosomes

Multiparameter Nanoparticle Tracking Analysis (NTA) - sizing, counting and zeta potential

ZetaView NTA-Zellkassette mit Blick auf die Ein- und Auslassöffnungen sowie den Durchfluss-Zellkanal.

PMX Technologies ZetaView Life Science Nanoparticle Tracking

Limitation of sample volume: How to recover a sample after NTA measurement

Full recovery of samples measured by a nanoparticle tracking analyzer (NTA) often becomes challenging particularly if the samples are intended for...

PMX Technologies Nanoparticle Tracking

How to measure the zeta potential of individual Nanoparticles (NPs)?

To anticipate the answer: With the ZetaView®.

ZetaView - High efficiency quantification of fluorescent labeled EVs with F-NTA

Technologies ZetaView Nanoparticle Tracking

High efficiency quantification of fluorescent labeled EVs with F-NTA

Nanoparticle Tracking Analysis (NTA) is an efficient technique for quantification of size and concentration such as virus, liposomes and EVs....

Surface Charge and Pattern Analysis -  Differentiating Tools in Scanning NTA

Technologies ZetaView Nanoparticle Tracking

Surface Charge and Pattern Analysis - Differentiating Tools in Scanning NTA

Nanoparticle Tracking Analysis (NTA) combined with surface charge measurement enables the user to gain bio-chemical information about particle...

ZetaView - With all Cell Assemblies, size, concentration and sub-population measurements are possible, in scattering and fluorescent mode

Technologies ZetaView Nanoparticle Tracking

The Scanning Nano Particle Tracking Analysis (NTA) ZetaView™ now for potentially hazardous samples

Particle Metrix now introduces two additional types of NTA Cell Assemblies: The new types are designed for concentration, size and fluorescence...

ZetaView Measurement Principle

Technologies ZetaView Nanoparticle Tracking

Introduction to Nanoparticle Tracking Analysis (NTA)

Measurement Principle of ZetaView®

Particle Tracking on Exosomes

Technologies ZetaView Nanoparticle Tracking

ZetaView® Particle Tracking on Exosomes

Multiparameter Nanoparticle Tracking Analysis (NTA) - sizing, counting and zeta potential

Operating ZetaView®

11 Positions Scan


To capture many individual particles in the field of view, the ZetaView® optic scans a wide field of the cell channel. In addition, additional sample volume is automatically added by means of a precise pump.

Nanoparticle Tracking Analysis (NTA) with ZetaView®

Brownian Diffusion in the Laser Scattering Video Microscope

120 nm Al203 particles and agglomerates in the electrophoresis set-up of ZetaView