Particle Metrix GmbH

Deutsch
English

 Home | Sitemap | Legal Notice | Contact | Login

ProductsParticle_SizeParticle_ShapeParticle_ChargeTechnologiesApplicationsNewsletterEventsNewsVideosAbout usDistributorsSearch
Zeta Potential

ZETA POTENTIAL AND SIZE DISTRIBUTIONS

 

 

Zetatrac

 

Microtrac has enhanced the functionality of the Nanotrac range of instruments to include Zeta Potential  measurement  capability.  The  determination  of  Zeta  Potential  provides  critical information to researchers and production personnel regarding the stability of a wide range of emulsions and colloidal suspensions.

 

Zetatrac utilizes  the unique Nanotrac probe  technology  to provide  fast, accurate,  convenient and cost effective Zeta Potential measurements without the need for disposable cuvettes.

One instrument—Three Measurements: 

  • Zeta Potential
  • Particle Size
  • Molecular Weight  
Zetatrac

Zetatrac measures Zeta Potential by determining the mobility of particles as they move from one side of the sample cell to the other. A potential difference is applied to the sample cell and charged particles move to the electrode of opposite polarity at a velocity proportional to their charge. Using the principles of Dynamic Light  Scattering, light from a laser is scattered and is frequency shifted under the Doppler Effect in relation to it’s velocity. By determining the velocity of the charged particle, the Zeta Potential can be calculated. Zetatrac uses Microtrac’s  proprietary Controlled Reference Method to generate a power spectrum (inverse of photon correlation curve) of the moving charged particles. Unlike other methods, Zetatrac can measure Zeta Potential in both high and low concentration suspensions.  

 

Zetatrac is controlled by Microtrac FLEX Operating Software. Through the use off Standard Operating Procedures (SOP’s), the user is guided through a series of easy steps to generate full characterization data on Zeta Potential and Particle Size. Data archiving and retrieval is through standard Microsoft Access™ database management with the ability to export data either manually or automatically. Graphic data presentations, report generation, trending and statistical analysis are all standard features of FLEX Software.

 

 

 

SPECIFICATIONS

 

Model


NPA151 - 31A Zetatrac

Internal Sample Cell Volumes


0.2 ml

Measurement Range

Size

Zeta Potential

0.8 to 6500 nanometers

3 nm to 10 microns

Measurement Angle

180 Degrees

Concentration Limits

High

Low

up to 40% by solids in some cases

0.1 mg/ml Lysozyme

Repeatability

Particle Size

Zeta Potential

1% for 100 nm Polystyrene

+/- 5mV,

+/- 0.4 mobility units, (microsecond/vol

Optical Components

Laser Diode

780 nm wavelength, 3 mW nominal, Class IIIB

Laser and detector fixed in place - no alignment required

Power requirements

90 to 240 VAC, 47 to 63 Hz, 5 Amps

Temperature (operating)

10 to 50 Degrees C

Humidity

up to 90% non condensing

Dimensions

Width

Depth

Height

10.2 cms (4 inches)

38.1 cms (15 inches)

15.2 cms (6 inches)

Weight

3.2 kgs (7 pounds)

 

 

  Download PDF-File